In many locations from chemistry laboratories to industrial amenities, to find a way to ensure the security of life and property in opposition to a attainable fireplace hazard, extinguishing methods are used along with detection and alarm systems. เกจวัดแรงดันแก๊สco2 is also extraordinarily necessary that the extinguishing methods put in could be triggered by the fireplace extinguishing management panel, in order to get rid of a potential fireplace with early intervention.
In order to satisfy these needs, and with 35 years of sectoral knowledge and expertise, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel working according to the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote performance of the indicators and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing process may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced using surface-mount know-how and are aimed toward making the automation of the extinguishing system and fireplace and gasoline detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times contemplating the needs of the set up. In cases that require the combination of the extinguishing system with the clever addressable fire detection system, it provides options through the monitoring modules that also have a ‘supervised’ option.
Supervised monitoring modules play an important role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or short circuit in the wiring between the contact monitoring modules and the peripheral techniques could cause disruption of the triggering, with probably crucial consequences. For this purpose, when choosing monitoring modules, it should be taken into consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable fire detection and alarm management panels are constantly communicating with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to monitor situations corresponding to open circuits and short circuits which will occur within the system. Many duties can be performed in the fire extinguishing set up, such because the control and monitoring of all valves that may interrupt the move of water, water flow alarm switches, stress switch, and electrical or diesel fireplace pumps.
By including two contact monitoring modules to 2 separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be used to control errors and the other to regulate the fire state of affairs, monitoring and control of the extinguishing system by way of an intelligent addressable fire detection and alarm system could be carried out effectively.
For extra info, go to www.mavili.com.tr/en